InfoScale™ 9.0 Cluster Server Agent Developer's Guide - AIX, Linux, Solaris, Windows
- Introduction
- Agent entry point overview
- About agent entry points
- Agent entry points described
- About the action entry point
- About the info entry point
- Considerations for using C++ or script entry points
- About the agent information file
- About the ArgList and ArgListValues attributes
- Creating entry points in C++
- About creating entry points in C++
- Syntax for C++ entry points
- Agent framework primitives
- Agent Framework primitives for container support
- Creating entry points in scripts
- About creating entry points in scripts
- Syntax for script entry points
- Agent framework primitives
- VCSAG_GET_ATTR_VALUE
- Agent Framework primitives with container support
- Example script entry points
- Logging agent messages
- Building a custom agent
- Building a script based IMF-aware custom agent
- Creating XML file required for AMF plugins to do resource registration for online and offline state monitoring
- Testing agents
- Static type attributes
- About static attributes
- Static type attribute definitions
- AdvDbg
- ArgList
- State transition diagram
- Internationalized messages
- Troubleshooting VCS resource's unexpected behavior using First Failure Data Capture (FFDC)
- Appendix A. Using pre-5.0 VCS agents
AlertOnMonitorTimeouts
Indicates the number of consecutive monitor failures after which VCS sends an SNMP notification to the user. A monitor attempt is considered a failure if it does not complete within the time specified by the MonitorTimeout attribute.
When a monitor fails as many times as the value or a multiple of the value specified by the AlertOnMonitorTimeouts attribute, then VCS sends an SNMP notification to the user. If this attribute is set to a value, say N, then after sending the notification at the first monitor timeout, VCS also sends an SNMP notification at each N-consecutive monitor timeout including the first monitor timeout for the second-time notification.
In case of monitor timeouts, the AlertOnMonitorTimeouts attribute can be used in conjunction with the FaultOnMonitorTimeouts attribute to control the behavior of resources of a group configured under VCS. When FaultOnMonitorTimeouts is set to 0 and AlertOnMonitorTimeouts is set to some value for all resources of a service group, then VCS will not perform any action on monitor timeouts for resources configured under that service group, but will only send notifications at the frequency set in the AlertOnMonitorTimeouts attribute.
Note:
This attribute applies only to online resources. If a resource is offline, no special action is taken during monitor failures.
When AlertOnMonitorTimeouts is set to 0, VCS sends an SNMP notification to the user only for the first monitor timeout; VCS does not send further notifications to the user for subsequent monitor timeouts until the monitor returns a success.
Default is 0. The AlertOnMonitorTimeouts attribute value can be overridden.