Veritas Access Appliance Release Notes
- Overview of Access Appliance
- Changes in this release
- Fixed issues
- Software limitations
- Limitations related to installation and upgrade
- Limitation related to replication
- Known issues
- Access Appliance known issues
- Admin issues
- CIFS issues
- General issues
- GUI issues
- Infrastructure issues
- Installation and configuration issues
- Internationalization (I18N) issues
- MSDP-C issues
- Networking issues
- NFS issues
- ObjectAccess issues
- Replication issues
- STIG issues
- Storage issues
- System issues
- Upgrade issues
- Veritas Data Deduplication issues
- Access Appliance operational notes
- Access Appliance known issues
- Getting help
During rolling upgrade, Access Appliance shutdown does not complete successfully
The Access Appliance shutdown operation does not complete successfully during rolling upgrade and the following error message is displayed:
vxfs failed to stop on <node-name>
(IA-14910)
Workaround:
When this issue occurs, the installer displays the following prompt:
Do you want to continue? [y,n,q] (n) y
Enter y and continue with the rolling upgrade.
The installer continues with phase 1 of rolling upgrade on the remaining nodes and exits before performing phase 2 of the upgrade on the cluster with the following message:
It is recommended to perform rolling upgrade phase 2 on all the cluster systems in the next step. Rerun the installer to do this after reboot. It is strongly recommended to reboot the following systems:<node-name>.
Restart the node before phase 2 of rolling upgrade. Verify that the node is up and has joined the cluster by executing the following command on the master node:
# vxclustadm nidmap
Verify that all the recovery tasks are complete by executing the following command on the master node:
# vxtask list
Check if the following keywords are present in the vxtask list command output:
ECREBUILD/ATCOPY/ATCPY/PLXATT/VXRECOVER/RESYNC/RECOV
If the keywords are not present, start the upgrade again using the following command:
./installaccess -rolling_upgrade
The installer asks if you want to proceed with phase 2 of rolling upgrade. Enter y to continue.
If the issues persist after restart, contact Technical Support.