Veritas InfoScale™ 7.4.2 Installation Guide - Linux
- Section I. Planning and preparation
- Introducing Veritas InfoScale
- Licensing Veritas InfoScale
- System requirements
- Preparing to install
- Setting up the private network
- Setting up shared storage
- Planning the installation setup for SF Oracle RAC and SF Sybase CE systems
- Section II. Installation of Veritas InfoScale
- Installing Veritas InfoScale using the installer
- Installing Veritas InfoScale using response files
- Installing Veritas Infoscale using operating system-specific methods
- Completing the post installation tasks
- Section III. Uninstallation of Veritas InfoScale
- Section IV. Installation reference
- Appendix A. Installation scripts
- Appendix B. Tunable files for installation
- Appendix C. Troubleshooting installation issues
About telemetry data collection in InfoScale
The Veritas Telemetry Collector is used to collect licensing and platform related information from InfoScale products as part of the Veritas Product Improvement Program. The Veritas Telemetry Collector sends this information to an edge server.
The information collected helps identify how customers deploy and use the product, and enables Veritas to manage customer licenses more efficiently. The edge server does not collect any private information and only uses information specific to product, licensing, and platform (which includes operating system and server hardware).
Table: Information sent by the collector
Category | Information attributes |
---|---|
Product |
|
Licensing |
|
Operating system |
|
Server hardware |
|
By default, the Veritas Telemetry Collector will collect telemetry data every Tuesday at 1:00 A.M. as per the local system time. The time and interval of data collection can be customized by the user if required.
You can configure the Veritas Telemetry Collector while installing or upgrading the product, See Installing Veritas InfoScale using the installer.. You can also manage the Veritas Telemetry Collector on each of your servers by using the /opt/VRTSvlic/tele/bin/TelemetryCollector command. For more information, See Managing the Veritas telemetry collector on your server.
Configure the firewall policy such that the ports required for telemetry data collection are not blocked. Refer to your respective firewall or OS vendor documents for the required configuration.
Note:
Ensure that you reboot the server after uninstalling the product to ensure that all services related to the Veritas Telemetry Collector are stopped successfully.