Description
Use these instructions to download and upgrade the NetBackup™ Flex Scale Appliances. This patch can be installed on NetBackup™ Flex Scale version 3.0. If you are on an earlier product version, upgrade to version 3.0 and install the patch. Veritas recommends that you install this update to make sure that you have the latest product fixes.
For details about the issues that are fixed in this release, see the Release Update.
About the NetBackup™ Flex Scale upgrade
Veritas NetBackup™ Flex Scale Appliances support the following upgrade methods:
- Rolling upgrade: Use this method if the NetBackup Flex Scale is configured and the appliance nodes are part of the cluster. During a rolling upgrade, each node in the cluster is upgraded successively without stopping the cluster. Rolling upgrade minimizes service downtime.
- Node-by-node upgrade: Use this method if the appliance nodes are in a factory state.
Downloading the appliance software release updates
Appliance software updates can be downloaded by using the NetBackup Flex Scale Appliance GUI. Updates must be downloaded to the appliance before you start the upgrade.
- For a rolling upgrade, download the software upgrade package to one of the nodes in the cluster and upgrade the node where the upgrade package is downloaded. The upgrade process
copies and installs the upgrade package to other nodes in the cluster. - For a node-by-node upgrade, download the software upgrade package to each node that you want to upgrade.
For the complete procedure to download the updates, see the Veritas NetBackup™ Flex Scale Installation and Configuration Guide on SORT.
Upgrading the NetBackup Flex Scale Appliance to 3.0.0.1
- For a rolling upgrade, install the software update on the node where you downloaded the upgrade package.
- For a node-by-node upgrade, install the software update on each node that you want to upgrade.
For the complete procedure to upgrade to version 3.0.0.1, see the Performing a patch upgrade using GUI section in the Veritas NetBackup™ Flex Scale Installation and Configuration Guide on SORT.
Viewing logs
The upgrade-related logs are listed below:
- Upgrade logs:
/log/app_vxul/409-777-*.log, /log/upgrade/*
- Preflight checks:
/log/app_vxul/409-776-*.log
,/log/preflight_check_report.json
- Software management:
/log/app_vxul/409-777-*.log
Download link for NetBackup Flex Scale software updates
Click the following link to download the NetBackup Flex Scale software version 3.0.0.1 update:
https://www.veritas.com/support/en_US/downloads/update.UPD677302