NetBackup appliances with version 3.2 require restart of NetBackup processes to enforce modified MSDP tuning parameters

Article: 100047662
Last Published: 2020-05-19
Ratings: 0 0
Product(s): Appliances

Problem

When you perform the role configuration during the initial configuration on appliances with version 3.2, some MSDP parameter settings are modified but do not take effect.

Error Message

Not applicable.

Cause

The modified MSDP parameter settings are not getting enforced automatically after completing the role configuration.

Solution

After you have completed the initial configuration of the appliance, immediately restart the NetBackup processes to enforce the modified MSDP parameters as follows:

  1. Log in to the NetBackup Appliance Shell Menu and navigate to Support > Processes.
  2. Run the following commands in the order as shown:
    Processes NetBackup Stop
    Processes NetBackup Start

Note: If you have already deployed 3.2 appliances into your production environment, you can restart the NetBackup processes as described above at a time that is most convenient for you.

Was this content helpful?