Important:
- This nbdeployutil Emergency Engineering Binary (EEB) contains a fix for the NetBackup Web Management Console web service. During the EEB installation, the web services are shut down and the services restart automatically after the installation is complete.
Ensure that there are no backup or restore jobs running when you install this EEB.
- If you uninstall this EEB, then the incremental runs of nbdeployutil will start afresh but will not have any impact on manual runs of nbdeployutil.
Description
This update to the nbdeployutil
for NetBackup 8.1.2 contains the fixes for the following issues:
Issue | Resolution |
---|---|
Usage data is not reported or updated on the NetBackup web user interface or Smart Meter. | If there are multiple policies of the same type are configured for a client, then For more information, refer to: |
Issue with the incremental run of nbdeployutil |
Scheduled incremental runs of nbdeployutil are missed due to an error in the day and time calculations. At midnight local time, If required, you can configure the time buffer using the following setting in
Where a minimum value can be 5 minutes and a maximum value is 720 minutes. For more information about configuration settings, refer to: Scheduling capacity licensing reports A sample of an
|
Issue with the /tmp folder while generating the licensing report in incremental mode. |
You can now configure a custom path for the
For more information, refer to: Scheduling capacity licensing reports A sample of an
|
Issue observed when one NetBackup master server is configured to generate capacity usage for other master servers. | An issue was observed while adding a NetBackup master server as a trusted master server to NetBackup 8..1.2 master server. The fix now lets NetBackup 8.1.2 generate reports using An issue is observed when a NetBackup master server gathers the usage data of a NetBackup 8.1.2 master server. The fix now lets you to generate reports correctly for NetBackup 8.1.2 master using |
Incorrect capacity usage for Oracle policy type with NetBackup client 8.1 or later. | In a few scenarios, the capacity usage is incorrectly reported and can be higher than actual. |
After upgrading NetBackup master to version 8.1.2, the incremental reports of nbdeployutil and the usage data in Veritas Smart Meter might incorrect for the VMWare policy types. |
This issue is observed after the NetBackup master server upgrades to 8.1.2 in the following scenarios:
|
Download the Emergency Engineering Binary from the following hotfix link:
https://www.veritas.com/support/en_US/downloads/update.UPD432977
If this link does not work the fix is now available in the Download Center as “NetBackup 8.1.2 Hotfix - nbdeployutil not generating Smart Meter usage file (Etrack 3983309)”