Problem
When you attempt to add the partner node to the high availability (HA) setup, the process may fail and show the following error:Error Message
- [Warning] V-409-955-4001: The NICs for the communication between the two nodes are not available or not connected.Cause
The NIC ports that are used for HA communication, NIC3/eth2 and NIC4/eth3 may not be available for any of the following reasons:
- The NIC ports are not connected correctly.
- One of the NIC ports on either node may be disconnected.
- One or both NIC ports on either node are part of a bonded interface.
Solution
- Log in to the NetBackup Appliance Shell Menu on each node.
- Run the following command to check if ports NIC3/eth2 and NIC4/eth3 are PLUGGED|UP or UNPLUGGED|DOWN:
Main_Menu > Network > Show Status - Run the command again to refresh the network information. If the result shows any of these ports as UNPLUGGED|DOWN, check the following port cable connections and network configurations and make the necessary corrections:
- Make sure that ports NIC3/eth2 and NIC4/eth3 are connected correctly between the two nodes. For detailed connection instructions, see the NetBackup 5330 Hardware Installation Guide or the NetBackup 5340 Hardware Installation Guide.
- Make sure that ports NIC3/eth2 and NIC4/eth3 on either node are not bonded.
References
UMI : V-409-955-4001