- Section I. Introduction to SFCFSHA
- Introducing Storage Foundation Cluster File System High Availability
- Section II. Configuration of SFCFSHA
- Preparing to configure
- Preparing to configure SFCFSHA clusters for data integrity
- About planning to configure I/O fencing
- Setting up the CP server
- Configuring the CP server manually
- Configuring SFCFSHA
- Configuring a secure cluster node by node
- Completing the SFCFSHA configuration
- Verifying and updating licenses on the system
- Configuring SFCFSHA clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Performing an automated SFCFSHA configuration using response files
- Performing an automated I/O fencing configuration using response files
- Configuring CP server using response files
- Manually configuring SFCFSHA clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the SFCFSHA cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Section III. Upgrade of SFCFSHA
- Planning to upgrade SFCFSHA
- Preparing to upgrade SFCFSHA
- Performing a full upgrade of SFCFSHA using the installer
- Performing a rolling upgrade of SFCFSHA
- Performing a phased upgrade of SFCFSHA
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated SFCFSHA upgrade using response files
- Upgrading Volume Replicator
- Upgrading VirtualStore
- Performing post-upgrade tasks
- Planning to upgrade SFCFSHA
- Section IV. Post-configuration tasks
- Section V. Configuration of disaster recovery environments
- Section VI. Adding and removing nodes
- Adding a node to SFCFSHA clusters
- Adding the node to a cluster manually
- Setting up the node to run in secure mode
- Adding a node using response files
- Configuring server-based fencing on the new node
- Removing a node from SFCFSHA clusters
- Adding a node to SFCFSHA clusters
- Section VII. Configuration and Upgrade reference
- Appendix A. Installation scripts
- Appendix B. Configuration files
- Appendix C. Configuring the secure shell or the remote shell for communications
- Appendix D. High availability agent information
- Appendix E. Sample SFCFSHA cluster setup diagrams for CP server-based I/O fencing
- Appendix F. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Using the UDP layer of IPv6 for LLT
- Manually configuring LLT over UDP using IPv6
- About configuring LLT over UDP multiport
- Appendix G. Using LLT over RDMA
- Configuring LLT over RDMA
- Configuring RDMA over an Ethernet network
- Configuring RDMA over an InfiniBand network
- Tuning system performance
- Manually configuring LLT over RDMA
- Troubleshooting LLT over RDMA
Verifying LLT configuration
After starting LLT, GAB and other component, run the following commands to verify the LLT configuration.
- Run the lltstat -l command to view the RDMA link configuration. View the link-type configured to rdma for the RDMA links.
# lltstat -l
LLT link information: link 0 link0 on rdma hipri mtu 8192, sap 0x2345, broadcast 192.168.27.255, addrlen 4 txpkts 171 txbytes 10492 rxpkts 105 rxbytes 5124 latehb 0 badcksum 0 errors 0
- Run the lltstat -nvv -r command to view the RDMA and non-RDMA channel connection state.
LLT internally configures each RDMA link in two modes (RDMA and non-RDMA) to allow both RDMA and non-RDMA traffic to use the same link. The GAB membership-related traffic goes over the non-RDMA channel while node to node data-transfer goes over high-speed RDMA channel for better performance.
# lltstat -rnvv active
LLT node information: Node State Link Status TxRDMA RxRDMA Address * 0 thorpc365 OPEN link0 UP UP UP 192.168.27.1 link1 UP UP UP 192.168.28.1 link2 UP N/A N/A 00:15:17:97:91:2E 1 thorpc366 OPEN link0 UP UP UP 192.168.27.2 link1 UP UP UP 192.168.28.2 link2 UP N/A N/A 00:15:17:97:A1:7C