Please enter search query.
Search <book_title>...
InfoScale™ 9.0 Cluster Server Configuration and Upgrade Guide - AIX
Last Published:
2025-04-21
Product(s):
InfoScale & Storage Foundation (9.0)
Platform: AIX
- Section I. Configuring Cluster Server using the script-based installer
- I/O fencing requirements
- Preparing to configure VCS clusters for data integrity
- About planning to configure I/O fencing
- Setting up the CP server
- Configuring VCS
- Configuring a secure cluster node by node
- Verifying and updating licenses on the system
- Configuring VCS clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Section II. Automated configuration using response files
- Performing an automated VCS configuration
- Performing an automated I/O fencing configuration using response files
- Section III. Manual configuration
- Manually configuring VCS
- Configuring LLT manually
- Configuring VCS manually
- Configuring VCS in single node mode
- Modifying the VCS configuration
- Manually configuring the clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the VCS cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Manually configuring VCS
- Section IV. Upgrading VCS
- Planning to upgrade VCS
- Performing a VCS upgrade using the installer
- Tasks to perform after upgrading to 2048 bit key and SHA256 signature certificates
- Performing an online upgrade
- Performing a phased upgrade of VCS
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated VCS upgrade using response files
- Planning to upgrade VCS
- Section V. Adding and removing cluster nodes
- Adding a node to a single-node cluster
- Adding a node to a single-node cluster
- Adding a node to a multi-node VCS cluster
- Manually adding a node to a cluster
- Setting up the node to run in secure mode
- Configuring I/O fencing on the new node
- Adding a node using response files
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Adding a node to a single-node cluster
- Section VI. Installation reference
- Appendix A. Services and ports
- Appendix B. Configuration files
- Appendix C. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Manually configuring LLT over UDP using IPv6
- Appendix D. Migrating LLT links from IPv4 to IPv6 or dual-stack
- Appendix E. Configuring the secure shell or the remote shell for communications
- Appendix F. Installation script options
- Appendix G. Troubleshooting VCS configuration
- Appendix H. Sample VCS cluster setup diagrams for CP server-based I/O fencing
- Appendix I. Changing NFS server major numbers for VxVM volumes
- Appendix J. Upgrading the Steward process
Verifying that the nodes have access to the same disk
Before you test the disks that you plan to use as shared data storage or as coordinator disks using the vxfentsthdw utility, you must verify that the systems see the same disk.
To verify that the nodes have access to the same disk
- Verify the connection of the shared storage for data to two of the nodes on which you installed Arctera InfoScale Enterprise.
- Ensure that both nodes are connected to the same disk during the testing. Use the vxfenadm command to verify the disk serial number.
# vxfenadm -i diskpath
For A/P arrays, run the vxfentsthdw command only on secondary paths.
Refer to the vxfenadm (1M) manual page.
For example, an EMC disk is accessible by the /dev/rhdisk75 path on node A and the /dev/rhdisk76 path on node B.
From node A, enter:
# vxfenadm -i /dev/rhdisk75
Vendor id : EMC Product id : SYMMETRIX Revision : 5567 Serial Number : 42031000a
The same serial number information should appear when you enter the equivalent command on node B using the /dev/rhdisk76 path.
On a disk from another manufacturer, Hitachi Data Systems, the output is different and may resemble:
Vendor id : HITACHI Product id : OPEN-3 Revision : 0117 Serial Number : 0401EB6F0002