Veritas™ 5260 Appliance Product Description Guide

Last Published:
Product(s): Appliances (Version Not Specified)
Platform: Veritas 5260
  1. About the Veritas 5260 Appliance
    1.  
      Veritas 5260 Appliance overview
    2.  
      Features and components of the Veritas 5260 Appliance
    3.  
      Locating the appliance serial number
    4. Veritas 5260 Appliance front panel drive configurations
      1.  
        About the drive LEDs
    5.  
      About the Veritas 5260 Appliance front panel USB port
    6. About the 5260 Appliance control panel
      1.  
        About the System Status LED states
      2.  
        About the Power button LED states
    7.  
      About the 5260 Appliance rear panel
    8. Veritas 5260 Appliance I/O configuration options
      1.  
        Veritas 5260 Appliance total I/O on-board and PCIe ports
      2.  
        Customizable I/O configurations by slot for existing Veritas 5260 Appliance
      3.  
        Broadcom P225p 10/25Gb PCIe Ethernet card
      4.  
        QLE2772 dual-port 32 Gb Fibre Channel host bus adapter
      5.  
        Intel RAID Adapter RS3P4MF088F
  2. Veritas 2U12 65.5TiB/72TB Storage Shelf
    1.  
      Storage Shelf overview
    2.  
      Usable appliance storage capacities
    3. Components of the Storage Shelf
      1.  
        Storage Shelf front panel components
      2.  
        Storage Shelf control panel
      3.  
        Storage Shelf rear components
      4.  
        Storage Shelf I/O modules
      5.  
        I/O module Status LED location and conditions
      6.  
        I/O module SAS Activity LED location and conditions
      7.  
        Storage Shelf Power Cooling Modules
      8.  
        Power Cooling Module LEDs
  3. Veritas 5260 Appliance and Veritas 2U12 65.5TiB/72TB Storage Shelf cables
    1.  
      Power cables
    2.  
      Network cable
    3.  
      Multi-Mode fiber optic cable
    4.  
      Twinaxial copper cables
    5.  
      SAS-3 cable
  4. Appendix A. Technical specifications, Environmental/Protocol standards, and Compliance standards
    1.  
      Veritas 5260 Appliance technical specifications
    2.  
      Veritas 2U12 65.5TiB/72TB Storage Shelf technical specifications
    3.  
      Environmental specifications
    4.  
      Protocol standards
    5.  
      Regulatory, compliance, and certification information
    6.  
      Product regulatory compliance
    7.  
      Country approvals
    8.  
      Product safety compliance
    9.  
      Product EMC Compliance - Class A Compliance
    10.  
      Product environmental compliance
  5.  
    Index

I/O module SAS Activity LED location and conditions

This section discusses the location of the SAS Activity LEDs on the I/O module and the SAS Activity LED conditions.

Figure: I/O module SAS Activity LED location

I/O module SAS Activity LED location

Table: I/O module SAS Activity LED conditions

Condition

Activity LED (green)

Fault LED (amber)

No Cable Present

Off

Off

Cable Present

All links up, no activity.

On

Off

Cable Present

All links up.

Flash with aggregate port activity

Off

Critical Fault

Any fault which causes operation of the cable to cease or fail to start.

For example, an OVERCURRENT trip.

Off

On

Non-Critical Fault

Any fault which does not cause the connection to cease operation.

For example, not all links established; OVERTEMPERATURE condition detected.

Flash with aggregate port activity