Veritas Access 3350 Appliance Product Description
- About the Access 3350 Appliance
- About 3350 compute node disk drive configurations
- About the compute node control panel
- Standard 3350 Appliance PCIe-based I/O configuration
- About the Veritas 5U84 Storage Shelves
- About Veritas Access 3350 Appliance storage shelves
- About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear components
- Access 3350 Appliance and 5U84 Storage Shelf cables
- Appendix A. Technical specifications, Environmental/Protocol standards, and Compliance standards
- Regulatory, compliance, and certification information
SAS3 host bus adapter connector locations and labels
The 3350 Appliance uses two 12Gb SAS3 host bus adapters through which data is transferred from each of the 3350 Appliance compute nodes to the 5U84 Primary Storage Shelf. Each SAS3 host bus adapter connects to the 5U84 Primary Storage Shelf using mini-SAS cables. One of the SAS3 host bus adapters is installed in PCIe slot 1 of PCIe riser assembly 2. The other host bus adapter is installed in slot 4 of PCIe riser assembly 1.
The following picture and table provides more information about the SAS connectors.
Table: SAS3 host bus adapter connector numbers and locations
Connector number | Connector location |
---|---|
Connector3 (used for connections to the 5U84 Primary Storage Shelf) | SAS3 host bus adapter 0 (PCIe slot 1) |
Connector2 (used for connections to the 5U84 Primary Storage Shelf) | SAS3 host bus adapter 0 (PCIe slot 1) |
Connector1 (not used) | SAS3 host bus adapter 0 (PCIe slot 1) |
Connector0 (not used) | SAS3 host bus adapter 0 (PCIe slot 1) |
Connector3 (used for connections to the 5U84 Primary Storage Shelf) | SAS3 host bus adapter 1 (PCIe slot 4) |
Connector2 (used for connections to the 5U84 Primary Storage Shelf) | SAS3 host bus adapter 1 (PCIe slot 4) |
Connector1 (not used) | SAS3 host bus adapter 1 (PCIe slot 4) |
Connector0 (not used) | SAS3 host bus adapter 1 (PCIe slot 4) |