Veritas InfoScale 7.1 Installation and Upgrade Guide - Windows
- Preinstallation and planning
- Installing the Veritas InfoScale products
- Upgrading to InfoScale products
- Performing the post upgrade tasks
- Administering the InfoScale product installation
- Uninstalling the InfoScale products
- Performing application upgrades in an InfoScale environment
- Upgrading Microsoft SQL Server
- Upgrading SQL Server 2008 to SQL Server 2008 R2
- Upgrading to later versions of SQL Server
- Upgrading SQL Server 2008 to SQL Server 2008 R2
- Upgrading Oracle
- Upgrading application service packs in an InfoScale environment
- Upgrading Microsoft SQL Server
- Appendix A. Services and ports
- Appendix B. Migrating from a third-party multi-pathing solution to DMP
Upgrading SFW HA
This section describes the tasks to be performed while upgrading SFW HA.
Supported upgrade path: SFW HA to InfoScale Enterprise
The upgrade tasks depend on whether or not replication is configured in your environment.
Note:
After the upgrade is complete, the installer wizard performs certain cleanup tasks and a command prompt is displayed for certain time. Ignore the prompt and continue with the further tasks. The command prompt closes after the cleanup tasks are complete. Do not close the command prompt before the cleanup tasks are complete. The cleanup tasks are aborted if you close the prompt.
The following figure lists the tasks to be performed to upgrade VCS, where replication is not configured.
Task | References |
---|---|
1 | |
2 | To take a service group offline using VCS Cluster Manager:
For more details about using the CLI to take the service group offline, refer to the Cluster ServerAdministrator's Guide. |
3 | See Installing the server components using the installation wizard. See Installing the server components using the command-line installer. |
4 | |
5 | To bring a service group online using VCS Cluster Manager:
For more details about using the CLI to bring the service group online, refer to the Cluster Server Administrator's Guide. |
The following figure lists the tasks to be performed to upgrade SFW HA, where replication is configured.
Task | Reference |
---|---|
1 | |
2 | See Preparing the primary and secondary sites for upgrading SFW HA in a Volume Replicator environment. |
3 | To take a service group offline using VCS Cluster Manager:
For more details about using the CLI to take the service group offline, refer to theCluster Server Administrator's Guide. |
4 | See Installing the server components using the installation wizard. See Installing the server components using the command-line installer. |
5 | |
6 | |
7 | To bring a service group online using VCS Cluster Manager:
For more details about using the CLI to bring the service group online, refer to the Cluster Server Administrator's Guide. |