Please enter search query.
Search <product_name> all support & community content...
Article: 100020441
Last Published: 2013-10-24
Ratings: 0 0
Product(s): NetBackup
Problem
Oracle backup fails with error code 174 when NetBackup spans tape.Solution
ISSUE:
WhenNetBackup spans tape, the Oracle backup fails with error code 174.
ENVIRONMENT:
NetBackup6.5.3
Mediaserver:HP-UX11.11
Tapelibrary:IBM tape library
DRIVER:atdd:3.5.0.88(Same problem:5.5.0.88 on HP-UX 11.23)
ERROR CODE/MESSAGE:
status174
BPTMlog:
................................................
14:49:21.876[12419] <2> vnet_vnetd_service_socket: vnet_vnetd.c.2042:VN_REQUEST_SERVICE_SOCKET: 6 0x00000006
14:49:21.876[12419] <2> vnet_vnetd_service_socket: vnet_vnetd.c.2057: service:bpdbm
14:49:21.890[12419] <2> logconnections: BPDBM CONNECT FROM <FROM IP.ID> TO<TO IP.ID>
14:49:22.310[12419] <16> write_data: write of 262144 bytes indicated only 0 bytes werewritten, errno = 0
14:49:22.310[12419] <2> check_error_history: just tpunmount: called from bptm line21076, EXIT_Status = 174
14:49:22.311[12419] <2> io_close: closing/usr/openv/netbackup/db/media/tpreq/drive_IBM.ULT3580-TD4.003, frombptm.c.18530
.................................................
SOLUTION:
Set thefollowing atdd driver variables to 1 by using the following commands:
/opt/OMImag/bin/atdd_cfg-s TRAILER <trailer> <instance>
/opt/OMImag/bin/atdd_cfg-s TRAILER 1 1 "where 1 is the trailer, and 1 is the first deviceinstance"
/opt/OMImag/bin/atdd_cfg-s TRAILER 1 2
/opt/OMImag/bin/atdd_cfg-s TRAILER 1 3
/opt/OMImag/bin/atdd_cfg-s TRAILER 1 4
Thenconfirmation of updating results:
/opt/OMImag/bin/atdd_cfg-g TRAILER <instance>
# ./atdd_cfg-g TRAILER 1
TRAILER:1
# ./atdd_cfg-g TRAILER 2
TRAILER:1
# ./atdd_cfg-g TRAILER 3
TRAILER:1
# ./atdd_cfg-g TRAILER 4
TRAILER:1
Notice: Theabove has to be done for all devices instances. However, the trailer value isnot constant, so after a reboot, it defaults back to 0. Therefore, it issuggested to add script of above commands to the initialization script ofsystem.